Type of disability: All

Bathroom and toilet: Rom 041 HCWC

Property Measurement Standard
Door handle has fittings for wheelchair users No Should be found if the door is outward opening
Size of room
Breadth 3000 mm
Depth 3000 mm
Space for movement in bathroom/toilet
Width 2400 mm Minst 1500 mm
Depth 2445 mm Minst 1500 mm
Passage/corridor width 2400 mm Minimum 900 mm
Toilet
Space to the left of WC 1245 mm Minimum 900 mm
Space to the right of WC 750 mm Minimum 900 mm
Height of the toilet seat 480 mm Between 480 and 500 mm.
Height of the flusher 835 mm Mellom 800 og 1200 mm
Distance before toilet to back wall (deactivated) 955 mm Minst 700mm
Handle fixed to the ceiling (for movement) No
Flushing No
Luminance contrast toilet / background good Should be good or medium
Arm supporter
Arm rest to the left of WC Yes Will be in place
Arm rest to the right of WC Yes Will be in place
Arm supports height over toilet seat 300 mm Ca. 300 mm
Sink
Height of the sink's upper edge 820 mm Highest 850 mm
Depth underneath the sink 160 mm Minst 670 mm i en dybde på minimum 500 mm fra fronten av servanten
Fixture Single lever faucet Should be single-lever, or electronic / pushbutton
Luminance contrast wash basin / background Good Should be good or medium
Soap holder next to hand wash
Operating height 930 mm Mellom 800 og 1200 mm
Distance from the inside corner 1435 mm Minimum 500 mm
Hand dryer/paper towel dispenser
Operating height 870 mm Mellom 800 og 1200 mm
Distance from the inside corner 0 mm Minimum 500 mm
Mirror
Height under mirror 845 mm Maximum 900 mm
Height over mirror 1010 mm Minimum 1950 mm
Tilted mirror No
Shower
Width of shower tub 750 mm Shower area at least 1600x1300 mm
Depth of shower tub 750 mm Shower area at least 1600x1300 mm
Width of the entrance 460 mm Minimum 860 mm
Height of the tub's upper edge 220 mm Maximum 25 mm
Hand shower Yes
Shower chair No Should be accessible
Handle No Will be in place
Fixture Twisting knob Should be single-lever, or electronic / pushbutton
Anti-scald temperature control Yes Should have scald protector
colour contrast between shower and room Medium Should be good or medium
Safety in bath
Door can be opened from the outside Yes
Door open outwards Yes Should be outward opening
Flooring Marked floor path
Bath mat No
Alarm button/pull-cord No
Light and contrast conditions in bathroom/toilet
Strength of light 85 lux Minimum 300 lux
Contrast between wall and floor Medium Should be good or medium
> Click to enlarge the images

Possible obstacles in the route to here

You are here

  1. Building: Fyllingsdalen VGS Hovedbygning
  2. Entrance: Hovedinngang
  3. Door: 036 Yttergang
  4. Door: 037 Hall
  5. Surface: 037 Hall
  6. Corridor or road: Kommunikasjonsvei 037 til HCWC
  7. Door: Dør til rom 041 HCWC
  8. Bathroom and toilet: Rom 041 HCWC