Type of disability: All

Corridor or road: Til ekspedisjon 115

Property Measurement Standard
Total length 5600 mm
Width 1500 mm At least 1500 mm
Surface of floor Linoleum, vinyl, other
Deviation from general breadth
Width due to permanent fixtures 1080 mm Minimum 1200 mm
Length narrowest section 1080 mm Lengde maksimalt 5000 mm dersom bredde 1200-1500 mm
Doors in the narrowest part No Skal ikke være dører dersom bredde mindre enn 1500 mm
Pillars in communication path No
Width due to interior 1080 mm Minimum 900 mm
Light and contrast conditions in access pathway
Lighting 880 lux Minst 100 lux
Dazzling backlight in communication path No Should be avoided
colour contrast between walls and floor good Skal være god eller middels - luminanskontrast minst 0,2
Luminance contrast columns against background Not relevant Skal være god eller middels, ellers må søyler merkes med kontrastmarkering i minst to høyder
Pillars contrast marked in at least two heights Not relevant Skal være kontrastmerket hvis kontrast uten markering er dårlig

Possible obstacles in the route to here

  • Incline :  8 %
  • Length :  1000 mm
  • Width :  1000 mm
  • Length past upper end :  0 mm
  • Length past lower end :  0 mm
  • Openings :  420 mm
  • Handrail - diameter :  50 mm
  • Incline :  12 %
  • Length past upper end :  0 mm
  • Length past lower end :  0 mm
  • Handrail - diameter :  50 mm

You are here

  1. Building: 108046 Hammerfest tollsted
  2. Ramp: Til hovedinngang
  3. Surface: Repos foran hovedinngang
  4. Entrance: Hovedinngang
  5. Door in entrance or communication path: Hovedinngangsdør
  6. Surface: VF
  7. Door in entrance or communication path: Til ekspedisjon og HC toalett
  8. Surface: Foran rampe
  9. Ramp: Til ekspedisjon
  10. Surface: Etter rampe