Type of disability: All

Bathroom and toilet: HC-toalett 148 1.etg.

Property Measurement Standard
Door handle has fittings for wheelchair users Yes Should be found if the door is outward opening
Size of room
Breadth 1970 mm
Depth 2250 mm
Space for movement in bathroom/toilet
Width 1510 mm Minst 1500 mm
Depth 1590 mm Minst 1500 mm
Passage/corridor width 900 mm Minimum 900 mm
Toilet
Space to the left of WC 770 mm Minimum 900 mm
Space to the right of WC 830 mm Minimum 900 mm
Height of the toilet seat 480 mm Between 480 and 500 mm.
Height of the flusher 800 mm Mellom 800 og 1200 mm
Distance before toilet to back wall (deactivated) 740 mm Minst 700mm
Handle fixed to the ceiling (for movement) No
Flushing No
Luminance contrast toilet / background Medium Should be good or medium
Arm supporter
Arm rest to the left of WC Yes Will be in place
Arm rest to the right of WC Yes Will be in place
Arm supports height over toilet seat 370 mm Ca. 300 mm
Sink
Height of the sink's upper edge 870 mm Highest 850 mm
Depth underneath the sink 300 mm Minst 670 mm i en dybde på minimum 500 mm fra fronten av servanten
Fixture One-handed or electronic Should be single-lever, or electronic / pushbutton
Luminance contrast wash basin / background Medium Should be good or medium
Soap holder next to hand wash
Operating height 1100 mm Mellom 800 og 1200 mm
Distance from the inside corner 500 mm Minimum 500 mm
Hand dryer/paper towel dispenser
Operating height 1230 mm Mellom 800 og 1200 mm
Distance from the inside corner 500 mm Minimum 500 mm
Mirror
Height under mirror 950 mm Maximum 900 mm
Height over mirror 1850 mm Minimum 1950 mm
Tilted mirror No
Safety in bath
Door can be opened from the outside No
Door open outwards Yes Should be outward opening
Flooring Marked floor path
Bath mat No
Visual fire alarm Yes Should have visual warning
Alarm button/pull-cord No
Circuit breakers and electrical equipment in bathroom/toilet
Height of light switch 1100 mm Mellom 800 og 1200 mm
Distance from inner corner light switch 600 mm Minimum 500 mm
Light and contrast conditions in bathroom/toilet
Strength of light 300 lux Minimum 300 lux
Contrast between wall and floor Good Should be good or medium
> Click to enlarge the images

Possible obstacles in the route to here

You are here

  1. Building: 112193 Nofima (tidl. Fiskeriforskning), Tromsø - Hovedkontor
  2. Entrance: Hovedinngang
  3. Door: Inngangsdør
  4. Door: Port
  5. Corridor or road: Korridor mot heis
  6. Door: Dør til HC-WC 148
  7. Bathroom and toilet: HC-toalett 148 1.etg.