Type of disability: All

Bathroom and toilet: 127 HC-toalett

Property Measurement Standard
Door handle has fittings for wheelchair users Yes Should be found if the door is outward opening
Size of room
Breadth 1870 mm
Depth 3000 mm
Space for movement in bathroom/toilet
Width 1870 mm Minst 1500 mm
Depth 2000 mm Minst 1500 mm
Passage/corridor width 900 mm Minimum 900 mm
Toilet
Space to the left of WC 580 mm Minimum 900 mm
Space to the right of WC 995 mm Minimum 900 mm
Height of the toilet seat 490 mm Between 480 and 500 mm.
Height of the flusher 890 mm Mellom 800 og 1200 mm
Distance before toilet to back wall (deactivated) 760 mm Minst 700mm
Handle fixed to the ceiling (for movement) No
Flushing No
Luminance contrast toilet / background good Should be good or medium
Arm supporter
Arm rest to the left of WC Yes Will be in place
Arm rest to the right of WC Yes Will be in place
Arm supports height over toilet seat 360 mm Ca. 300 mm
Sink
Height of the sink's upper edge 780 mm Highest 850 mm
Depth underneath the sink 500 mm Minst 670 mm i en dybde på minimum 500 mm fra fronten av servanten
Fixture Single lever faucet Should be single-lever, or electronic / pushbutton
Luminance contrast wash basin / background Good Should be good or medium
Soap holder next to hand wash
Operating height 795 mm Mellom 800 og 1200 mm
Distance from the inside corner 200 mm Minimum 500 mm
Hand dryer/paper towel dispenser
Operating height 1220 mm Mellom 800 og 1200 mm
Distance from the inside corner 480 mm Minimum 500 mm
Mirror
Height under mirror 825 mm Maximum 900 mm
Height over mirror 1870 mm Minimum 1950 mm
Tilted mirror No
Shower
Width of shower tub 835 mm Shower area at least 1600x1300 mm
Depth of shower tub 860 mm Shower area at least 1600x1300 mm
Width of the entrance 480 mm Minimum 860 mm
Height of the tub's upper edge 280 mm Maximum 25 mm
Operating height for arm rests in shower 1025 mm Between 800 and 900 mm
Hand shower Yes
Shower head with adjustable height Yes Should be height-adjustable
Shower chair No Should be accessible
Handle No Will be in place
Fixture Twisting knob Should be single-lever, or electronic / pushbutton
Anti-scald temperature control Yes Should have scald protector
colour contrast between shower and room Good Should be good or medium
Safety in bath
Door can be opened from the outside Yes
Door open outwards Yes Should be outward opening
Flooring Marked floor path
Bath mat No
Visual fire alarm Yes Should have visual warning
Alarm button/pull-cord No
Light and contrast conditions in bathroom/toilet
Strength of light 500 lux Minimum 300 lux
Contrast between wall and floor Good Should be good or medium
> Click to enlarge the images

Possible obstacles in the route to here

  • Width in front of the lift :  1486 mm
  • Distance from the inside corner :  180 mm
  • Depth of lift :  1400 mm
  • Seatingarrangement in the lift :  No
  • Mirror :  Another placement
  • Nedre høyde speil :  940
  • Acoustic floor description :  None
  • Høyde etasjeangivelse :  1820

You are here

  1. Building: Langhaugen vg skole, Hovedbygning
  2. Starting point: Startpunkt
  3. Square : Skoleplass
  4. Entrance: Hovedinngang
  5. Door in entrance or communication path: Dør i hovedinngang
  6. Room: U01 Vindfang
  7. Door in entrance or communication path: Dør U01/U02 Kantine
  8. Cafeteria, conference room: U02 Kantine
  9. Door: Dør U02/U05 Trapperom
  10. Door in entrance or communication path: Dør U05/U17 Korridor
  11. Corridor or road: U17 Korridor
  12. Lift: Hovedheis
  13. Floor: Etasje - 1
  14. Corridor or road: 124a Korridor
  15. Door: Dør 124a/127 HC-toalett
  16. Bathroom and toilet: 127 HC-toalett