Type of disability: All

Bathroom and toilet: HC-WC 117

Property Measurement Standard
Door handle has fittings for wheelchair users No Should be found if the door is outward opening
Size of room
Breadth 2040 mm
Depth 1980 mm
Space for movement in bathroom/toilet
Width 1500 mm Minst 1500 mm
Depth 1350 mm Minst 1500 mm
Passage/corridor width 760 mm Minimum 900 mm
Toilet
Space to the left of WC 290 mm Minimum 900 mm
Space to the right of WC 1350 mm Minimum 900 mm
Height of the toilet seat 500 mm Between 480 and 500 mm.
Distance before toilet to back wall (deactivated) 800 mm Minst 700mm
Luminance contrast toilet / background bad Should be good or medium
Safety in bath
Circuit breakers and electrical equipment in bathroom/toilet
Height of light switch 1000 mm Mellom 800 og 1200 mm
Distance from inner corner light switch 860 mm Minimum 500 mm
Light and contrast conditions in bathroom/toilet
Contrast between wall and floor Good Should be good or medium
> Click to enlarge the images

Possible obstacles in the route to this destination

  • Incline :  8 %
  • Length :  1000 mm
  • Width :  1000 mm
  • Length past upper end :  0 mm
  • Length past lower end :  0 mm
  • Openings :  420 mm
  • Handrail - diameter :  50 mm
  • Incline :  12 %
  • Length past upper end :  0 mm
  • Length past lower end :  0 mm
  • Handrail - diameter :  50 mm
  • Length behind :  1350 mm
  • Height over floor :  1560 mm
  • Height of lettering :  20 mm
  • Contrast :  Medium
  • Sign placed at door lock level :  No

You are here

  1. Building: 108046 Hammerfest tollsted
  2. Ramp: Til hovedinngang
  3. Surface: Repos foran hovedinngang
  4. Entrance: Hovedinngang
  5. Door in entrance or communication path: Hovedinngangsdør
  6. Surface: VF
  7. Door in entrance or communication path: Til ekspedisjon og HC toalett
  8. Surface: Foran rampe
  9. Ramp: Til ekspedisjon
  10. Surface: Etter rampe
  11. Corridor or road: Til ekspedisjon 115
  12. Door: Til HC-WC 117
  13. Bathroom and toilet: HC-WC 117