Type of disability: All

Bathroom and toilet: HC-toalett

Property Measurement Standard
Door handle has fittings for wheelchair users No Should be found if the door is outward opening
Size of room
Breadth 1985 mm
Depth 1185 mm
Space for movement in bathroom/toilet
Width 970 mm Minst 1500 mm
Depth 1115 mm Minst 1500 mm
Passage/corridor width 860 mm Minimum 900 mm
Toilet
Space to the left of WC 555 mm Minimum 900 mm
Space to the right of WC 320 mm Minimum 900 mm
Height of the toilet seat 485 mm Between 480 and 500 mm.
Distance before toilet to back wall (deactivated) 610 mm Minst 700mm
Luminance contrast toilet / background bad Should be good or medium
Safety in bath
Light and contrast conditions in bathroom/toilet
Contrast between wall and floor Good Should be good or medium

Possible obstacles in the route to this destination

  • Length behind :  1185 mm
  • Height over floor :  1575 mm
  • Height of lettering :  55 mm
  • Sign placed at door lock level :  No

You are here

  1. Building: Indre Arna Tannklinikk
  2. Entrance: Hovedinngang
  3. Door in entrance or communication path: Hovedinngang
  4. Door in entrance or communication path: Dør fra vindfang
  5. Corridor or road: Gang til venterom
  6. Door: Til hc-toalett
  7. Bathroom and toilet: HC-toalett